Home > Products > Inhibition zone readers > Scan® 1200 inhibition zone reader

Scan® 1200 inhibition zone reader

HD inhibition zone reader

Ref. 437 000


Scan® 1200 is a HD inhibition zone reader enabling great reliability and user comfort for accurate results, excellent reproducibility and automatic saving of all data, images, comments and results.

-Traceability & High-performance


Advantages

1. HIGH RESOLUTION AND ACCURACY
- Instant: between 1and 3 seconds per Petri dish, result is categorized SIR (Sensitive, Intermediate, Resistant)
- High resolution: enables to read the letters on the dish
- Automatic detection with manual control
- Reads on: Muller Hinton agar, blood agar, chocolate agar
- Accuracy of inhibition zone measurement: 0.3 mm

2. INTERPRETATION SYSTEM
- CA-SFM Human Health
- EUCAST (The European Committee on Antimicrobial Susceptibility Testing)
- Customizable list (Fondamental research, CA-SFM Veterinary…)

3. GREAT LIGHTING
- Dark Field lighting set for translucid agar (such as MH, TS…)
- Double lighting set for opaque agar (such as blood, chocolate…)
- Maximum number of read discs: up to 8 antibiotics on 1 ø 90mm Petri dish

4. DATA SECURIZATION
- Traceability of modification in compliance with CFR21
- Connexion to LIMS / SIL systems

5. FULL TRACEABILITY
- Results harmonization within a team
- Automatic archive and print of reports: photos, comments, results
- Traceability (saving of sessions, Excel™, PDF, JPEG, BMP, Scan® printed report)
- External traceability(bar-code reader, file archive, LIMS connexion)
- Session securization (in compliance with CFR 21 part 11: system securization, operation control and documentation management)

Technical specifications

Technical specifications of the model.
Scroll down for the comparison with other models of the range.

Scan® 1200
Reference
437 000
Camera
HD CCD color camera
Digital zoom
x 28, enables to read the letters of the disks
Resolution
1.2 megapixels
Inhibition zones measurement
Automatic with manual control
Automatic detection
Paper disks (several brands simultaneously), wells, peni-cylinder (steel, plastic)
with possibility to add or remove manually
Reading time
Up to 8 antibiotics on a ø 90mm Petri dish between 1 and 3 seconds
Inhibition zone reader
oui
Inhibition zone measurement accuracy
0.1 mm
Reads on
Muller Hinton agar, blood agar, chocolate agar
Lighting
Long-lasting white LEDs / Dark Field / double lighting
Lighting system
Automatic: 6 combinations, white lighting
from under and/or above, black background
Reader
Automatic with manual control
Interpretation systems
CA-SFM Human health / EUCAST / Cutomizable list
(CA-SFM Veterinary, Fondamental research
Antibiotic detection
Automatic with manual control:
add / remove antibiotic manually
Data securization
Traceability of modifications in compliance with
CFR21 guidelines / Connexion to LIMS / SIL systems
Results / Traceability
Image / sample number / antibiotic name / bacteria number / read diameter / result categorized SIR (with color code) / critical diameter mini and max / comments / date / time
Photo export
BMP, PNG, JPEG
Data export/ résultats
OpenOffice / Excel / PDF
Systems connexion
LIMS/SIL via spreadsheet
Languages
english, french, japanese, chinese, russian, spanish
Dimensions (W x D x H)
27 x 27 x 38 cm
Weight
8.7 kg
Features
USB
Power
100-240 V   50/60 Hz
Operating system
Windows™: 7 SP1, 8
Processor
Intel Core (recommended) or AMD Phenom and superior, 2.4 GHz
RAM
3 Go
Features
USB port/ CD-ROM reader
Screen
1280 X 1024 pixels and more
Computer
Desktop computer recommended
Body
All stainless steel
Software update (after registration)
3 years
Guarantee (after registration)
3 years
In compliance with
GLP (Good laboratory Practice), CFR 21 part 11, ISO 15189, ISO 7218, ISO 4833-2, NF V08-034, NF V08-100, AOAC 977.27, FDA-BAM standards

Delivered with: Scan® software CD-ROM / connection cables / 3 control dishes / User’s Manual IQ/OQ/PQ guidelines / Quick user guide

Comparison with other models of the range
Scan® 300Scan® 500Scan® 1200Scan® 4000
Reference
436 300
436 000
437 000
438 000
Camera
CCD color camera
CMOS color camera
HD CCD color camera
Ultra HD CCD color camera
Digital zoom
x 28
x 64
Resolution
1 megapixels
1.2 megapixels
5 megapixels
Counting time
1000 colonies per second
Minimum colony size
0.1 mm
0.05 mm
Lighting
Long-lasting white LEDs / Dark Field
White Dome LED
Lighting system
Automatic: 6 combinations, white lighting from top/bottom, black/white background
Counting
Automatic with manual control
Counting on Petri dishes
55-90 mm
Round and square Petri 55-150 mm
Counting on pour, surface, Spiral® and circle plated dishes
oui
Counting on chromogenic dishes
-
oui
Inhibition zone measurement
-
oui
Inhibition zone measurement accuracy
-
0.3 mm
0.3 mm
0.1 mm
Reads on
-
Muller Hinton agar, blood agar, chocolate agar
Counting on PetriFilm™
-
oui
Counting on RIDA™ Count
-
oui
Counting on Compact Dry™
-
oui
Counting on filtration membranes
-
oui
Results / data export
Recountable Scan® file, PDF report,
JPEG, PNG, BMP, Excel™
Colour detection
-
7 colors on the same dish
LIMS/SIL connection
oui
USB connection
oui
Languages
Anglais, Français, Japonais, Chinois, Russe, Espagnol
Dimensions (l x p x h)
27 x 27 x 29 cm
27 x 27 x 38 cm
47 x 47 x 64 cm
Weight
6,6 kg
8,7 kg
24,4 kg
Power
100-240 V 50/60 Hz
Processor
Intel Core i3, i5 or i7 or AMD FX série 8000 or superior
(Quad-core recommended) Intel i5 or i7 or AMD FX 6000 or superior
Operating system
Windows™ 7 Service Pack 1 or Windows™ 8 or ulterior
Frequency
2,5 Ghz or superior
2,4 Ghz or superior
RAM
4 Ghz or superior
3 Go
Graphic card
NVIDIA or AMD (ATI)
AMD or NVIDIA (chipsets not recommended)
Ports
CD-ROM reader, port USB 2.0 minimum
Screen
1280 X 1024 pixels and more
Computer
Desktop recommended
Hardware
Stainless steel
Software update (after registration)
3 years
Guarantee (after registration)
3 years
In compliance with
GLP (Good laboratory Practice), CFR 21 part 11, ISO 15189, ISO 7218, ISO 4833-2, NF V08-034, NF V08-100, AOAC 977.27, FDA-BAM standards

Certified

  • Products made for INTERSCIENCE by Interlab, an ISO 9001 certified company.

Accessories

410 100 - dataLink
410 100 - dataLink
410 110 - Sticker for printer
410 110 - Sticker for printer
436 005 - Adaptor for Petri dish (55 mm)
436 005 - Adaptor for Petri dish (55 mm)
No picture
437 001 - Adaptor for Sanita-Kun™ RIDA™ Count
437 001 - Adaptor for Sanita-Kun™ RIDA™ Count
DataLink™ Printer stickers Petri dishes adaptors (55 mm) PC computer for automatic colony counters Sanita-Kun™ RIDA™ Count adaptors
Ref. 410 100 Ref. 410 110 Ref. 436 005 Ref. 436 100 Ref. 437 001
437 002 - Adaptor for Petri-Film™
437 002 - Adaptor for Petri-Film™
437 004 - Adaptor for Compact Dry™
437 004 - Adaptor for Compact Dry™
522 000 - Bar-code reader
522 000 - Bar-code reader
Petri-Film™adaptors Compact Dry™adaptors Bar-code reader
Ref. 437 002 Ref. 437 004 Ref. 522 000

F.A.Q

How does it work?
- Scan® 1200 operates the automatic detection of paper disks (all brands simultaneously), wells, peni-cylinders (steel, plastic) with manual control (possible to add/remove manually)

What is the maximum number of read antibiotics ?
- Scan® 1200 reads up to 8 antibiotics on 1 ø 90mm Petri dish

How about the reading time ?
- It is quick. Scan® 1200 reads up to 8 antibiotics on a ø 90mm Petri dish and measures 8 inhibitions zones between 1and 3 seconds.

Does Scan® 1200 mesures inhibition zones on translucid agar?
- Yes, Scan® 1200 is equipped with a Dark Field lighting system for translucid agar such as MH, TS…)

Does it work on dark agar?
- Yes, Scan® 1200 is equipped with a double lighting system, from the top and from bottom for opaque agar sych as chocolate, blood…

Is there a zoom?
- Yes. The zoom goes up to X28, enabling to read the letters on the disk.

What is the traceability of data?
- The saved data is: image (before /after analysis) / number of sample / name of antibiotics / name of the bacteria / read diameter / result categorized SIR (with color code) / critical diameter mini and maxi / comments / date / time

What are the applications of the Scan® 1200 Inhibition zone?
- Scan® 1200 inhibition zone is widely used in pharmaceutical microbiology, medical, veterianry and environmental.

Downloads

Please go to the Download section for :
High-definition photos / Illustrations / Videos / Scientific articles / Various marketing tools

- TECHNICAL FILE Scan® 1200 Inhibition Zone

fiche

- BROCHURE Scan® range

brochure

- FLYER dataLinkTM

PDF - 1.4 Mb



interscience Laboratories Inc  
32 Cummings Park, WOBURN, MA 01801 USA
Tel: 781 937 0007 | Fax: 781 937 0017 | sales.usa at interscience.com
Home | Site Map | Legal info | Webmaster All rights reserved © INTERSCIENCE 2017