Ventajas
HIGH QUALITY
Stainless steel body
Ultra HD CCD color camera
Digital zoom x 69
Resolution: 5 megapixels
Counting time: up to 1000 colonies per second
Minimum size of colony: 0.05 mm
THE LARGEST READING RANGE ON THE MARKET
Counting on round Petri dishes Ø 55 to 150 mm
Counting on 120 mm square Petri dishes
Counting on: PetriFilmTM, MC-Media PadsTM, Compact DryTM, filtration membranes, chromogenic dishes
UNEQUALLED LIGHTING
360° LED lighting, without reflection or shadow of the dish with White LED Dome technology
Ultra HD CCD 5 megapixels camera, detects bare eye invisible details
Beam Splitter to ensure lighting 100% without reflections or shadows
Automatic detection of the dish + reading on 100% of the dish
SOFTWARE EFFICIENCY
Automatic optimization of the contrast, luminosity and sensitivity
Automatic corrections of the agar defects
Automatic separation of confluent colonies
Creation of polygonal exclusion zones
Pre-set medias: Pca/Tsa, Mrs, Vrbl/Vrbg, Tbx, Tsc, Baird Parker, Gvpc Bcye, YM, Rapid L.Mono, Rapid Entero, Rhapsody, Compass cereus, PetriFilmTM, MC-Media PadsTM, Compact DryTM
FULL TRACEABILITY
Automatic archiving and printing of data: pictures, comments & results
Traceability: Session archived and saved, Excel™, PDF, JPEG, BMP, Scan printed report, barcode, file archive, LIMS connection
Securization of the sessions (Compliance with CFR 21 part 11: system securization, operational controls and documentation management)
EXCELLENT REPRODUCIBILITY AND REPEATABILITY
GLP (Good laboratory Practice)
The Scan 4000 counts with up to 98 % accuracy in a constant and repeatable way
Scan SOFTWARE
Scan automatic colony counters use an exclusive software developped by INTERSCIENCE: evolutive, user-friendly and powerful.
There are numerous advantages in using Scan counting software:
Only one clic to count
Only one setting cursor
Traceability: automatic saving of data, Excel™ export
VISUALISATION WINDOW
Detected colonies are highlighted and marked with a cross.
PARAMETERS WINDOW
Only one cursor to optimize counting. customizable settings adaptable to any kind of agar.
RESULTS WINDOW
All previously recorded data can be checked anytime.
EASY DATA EXPORT
Work sessions saving
Scan printed report
Results exported to Excel™
PDF export
JPEG, BMP export
EXAMPLE OF A SCAN PRINTED REPORT
Videos
Especificaciones técnicas
Technical specifications of the model.
Scroll down for the comparison with other models of the range.
Scan 4000 | |
---|---|
Reference | |
Hardware | |
Camera | |
Lens | |
Digital zoom | |
Resolution | |
Counting time | |
Minimum size colony | |
Lighting technology | |
Lighting system | |
Counting | |
Counting on Petri dishes | 120 mm square Petri dishes |
Counting on pour, surface, Spiral and circle plated dishes | ![]() |
Counting on chromogenic dishes | ![]() |
Inhibition zone reader | ![]() |
Counting on PetriFilm™ | ![]() |
Counting on MC-Media Pads™ | ![]() |
Counting on Compact Dry™ | ![]() |
Counting on filtration membranes | ![]() |
Automatic separation of clustered colonies | ![]() |
Creation of polygonal exclusion zones | ![]() |
Manual control to add or substract colonies | ![]() |
Data export | |
Color detection | |
LIMS/SIL connection | ![]() |
USB connection | ![]() |
Compatible with DataLink traceability system | ![]() |
Data security | |
Languages | |
Dimensions (w x d x h) | |
Weight | |
Voltage and frequency | |
Max power | |
Processor | |
Operating system | |
Frequency | |
RAM | |
Equipment | |
Screen | |
Graphic card | |
Software update | |
Warranty | |
In compliance with |
Delivered with : 1 Scan software / 1 connection cable / 3 control dishes / 1 user’s manual/ 1 quick user guide
Scan 300 | Scan 500 | Scan 1200 | Scan 4000 | |
---|---|---|---|---|
Reference | ||||
Camera | CMOS |
HD CCD |
ultra HD CMOS | |
Lens | ||||
Digital zoom | ||||
Resolution | ||||
Counting time | ||||
Minimum size colony | ||||
Lighting technology | ||||
Lighting system | ||||
Counting | ||||
Counting on Petri dishes | 120 mm square Petri dishes | |||
Counting on pour, surface, Spiral and circle plated dishes | ![]() | |||
Counting on chromogenic dishes | ![]() | |||
Inhibition zone reader | ![]() | |||
Counting on PetriFilm™ | ![]() | |||
Counting on MC-Media Pads™ | ![]() | |||
Counting on Compact Dry™ | ![]() | |||
Counting on filtration membranes | ![]() | |||
Automatic separation of clustered colonies | ![]() | |||
Data export | ||||
Color detection | ||||
Creation of polygonal exclusion zones | ![]() | |||
Manual control to add or substract colonies | ![]() | |||
LIMS connection | ![]() | |||
USB connection | ![]() | |||
Compatible with DataLink traceability system | ![]() | |||
Languages | ||||
Dimensions (w x d x h) | ||||
Weight | ||||
Voltage and frequency | ||||
Max power | ||||
Processor | or better |
or AMD FX 6000 or superior | ||
Operating system | ||||
Frequency | ||||
RAM | ||||
Graphic card | ||||
Equipement | ||||
Screen | ||||
Computer | ||||
Hardware | ||||
Softare update | ||||
Warranty | ||||
In conformity with |
Certificado
- Producto hecho para INTERSCIENCE por Interlab, empresa certificada ISO 9001.
GLP (Good laboratory Practice)
Accesorios
| |||
DataLink™ | Sticker for printer | Film | Bar-code reader |
Ref. 410 100 | Réf. 410 120 | Ref. 410 130 | Ref. 522 000 |
Descargas
FICHA TECHNICA
Ficha téchnica Scan 4000
FOLLETO
Folleto Scan 4000
FLYER
Flyer DataLink