BagFilter XF is a blender bag with a non-woven side filter. It is particularly suitable for samples containing fine particles. BagFilter XF is ideal for optimal use of capillary analysis systems (flow cytometry, PCR, qPCR, Spiral ...)

  • Filter porosity: < 20 micrometers
  • Compatible with any laboratory blender
  • Multilayer: reinforced multicoated complex
  • Rigid and transparent

Presentation

One bag for the full analysis

With BagFilter, use the same bag to sample, blend, filter and pipet. This will prevent cross-contamination and save time.


Prélever échantillon

1. Place the sample


Diluer échantillon

2. Dilute the sample


Homogeneiser échantillon

3. Blend the sample


Pipeter filtrat

4. Pipet the filtrate


BagFilter XF

Extra-low porosity filter

BagFilter XF is a bag with an extra-low porosity side filter: <20 microns. It is ideal for samples containing fine particles (powders, dusts, spices...) and organic elements. BagFilter XF is used for capillary analysis systems (PCR, flow cytometry...).


BagFilter XF - Extra-low porosity filter

Extra-low porosity filter < 20 µm

Instant filtration

Filtration is done during blending. There is no need to wait for sedimentation of the debris to pipet.

The filtrate is particle-free, so there is no debris on the Petri dish. Reading is thus facilitated and the results more precise.


Instant filtration


Instant filtration - No blocked pipet

No blocked pipet from particles


Instant filtration - Debris free

Debris free

No cross-contaminations

There is no contact between the sample and the mixer during homogenization. This avoids cross-contamination.

The bag can be closed with a BagClip or welded. It is processed by gamma ray.


Blender - risks of contaminations

Before


BagFilter P - Lab blender

After

Applications

BagFilter XF is used according to the protocols in food, pharmaceutical, cosmetic, environmental and public research institutes. BagFilter XF is suited for capillary analysis systems such as flow cytometry and PCR. BagFilter XF is ideal for samples with fine particles (spices, powders, dust...). It is also designed to separate the organic elements of the filtrate (fat, sugar, food gum, excipients...)


Food


Pharmaceutical


Cosmetic


Environment


Public research

Videos

Videos

From sample preparation to bacterial analyses - Overview

Download the video

From sampling to bacterial counting - Overview

Download the video

BagSystem - Increase your sample preparation

Download the video

BagFilter - Lateral filter blender bags: Overview of the range

Download the video

Resources

Resources

Title
Language
Type
Size
Download
PDF
13.3 Mb
Language: English
Blender bags brochure
PDF
798.4 kb
Language: English
BagFilter XF technical file
PDF
557.3 kb
Language: English, french
ISO 9001 Certificate
PDF
46.9 Mb
Language: English
English catalog
Z
Zip
1 Mb
Bag Range picture
Z
Zip
630.5 kb
BagFilter range picture
Z
Zip
696.5 kb
BagFilter XF photo
Z
Zip
1.1 Mb
BagFilter XF picture
Title
Language
Type
Size
Download
Title
Language
Type
Size
Download
Title
Language
Type
Size
Download
Title
Language
Type
Size
Download
Title
Language
Type
Size
Download
Title
Language
Type
Size
Download

Specifications

Specifications

BagFilter XF 400
Reference 111 325
Ideal For the use of PCR methods and samples with small particles (powders, cosmetics)
Max blending volume 400 mL
Optimal blending volume 50-300 mL
Type of bag Bag with lateral filter
Bag composition Multilayer : reinforced multicoated complex
Type of filter Lateral non-woven filter
Filter porosity < 20 micrometers
Bag dimensions 190 x 300 mm
Gamma ray treated 5 to 12 KGy
Average shelf-life 10 years
Resistant to freezing and high temperatures -40°C to 80°C (-40°F to 176°F)
In compliance with ISO 7218, ISO 6887 and FDA BAM (Bacteriological Analytical Manual)
Approved for food contact Regulation (EC) N° 1935/2004
Storage conditions In a temperate and dry place, away from humidity and light
Box (w x d x h) 35 x 22 x 15 cm
Gross weight 6 kg
Pack of 25
Box of 500
BagFilter XF 400
Reference 111 325
Ideal For the use of PCR methods and samples with small particles (powders, cosmetics)
Max blending volume 400 mL
Optimal blending volume 50-300 mL
Type of bag Bag with lateral filter
Bag composition Multilayer : reinforced multicoated complex
Type of filter Lateral non-woven filter
Filter porosity < 20 micrometers
Bag dimensions 190 x 300 mm
Gamma ray treated 5 to 12 KGy
Average shelf-life 10 years
Resistant to freezing and high temperatures -40°C to 80°C (-40°F to 176°F)
In compliance with ISO 7218, ISO 6887 and FDA BAM (Bacteriological Analytical Manual)
Approved for food contact Regulation (EC) N° 1935/2004
Storage conditions In a temperate and dry place, away from humidity and light
Box (w x d x h) 35 x 22 x 15 cm
Gross weight 6 kg
Pack of 25