Interscience for microbiology
  • English English
    • français Français
    • Deutsch Deutsch
    • Español Español
    • 日本語 日本語
    • 中文 中文
  • PRODUCTS
  • APPLICATIONS
  • RESOURCES
  • SUPPORT
  • COMPANY
  • CONTACT
Sample preparation
  • Gravimetric dilutors
  • Lab blenders
  • NEWDispensing pumps
  • Lab accessories
Bacterial analysis
  • Automatic platers
  • NEWColony counters and inhibition zone readers
  • Real-time incubator and colony counter
  • NEWPetri dish labeling solution
Consumables
  • Blender bags with filter
  • Blender bags without filter
  • Blender bags with culture media
  • Sterile sampling bags
  • Autoclave deodorants
NEWDiscover our catalog
More
Sectors
  • Food
  • Pharmaceutical
  • Cosmetic
  • Environment
  • Veterinary
  • Public research
Solutions
  • BagSystem
  • Plate & Count system
  • JumboLine
  • Steriwater
Application advice
  • Comparison of manual and automatic methods in microbiology
  • Why use a filter bag?
  • The Spiral plating technique
Discover our solutions for microbiology
More
Scientific library
  • Application notes
  • Scientific articles
  • Scientific posters
  • Appli’News
Training
  • Webinars
Downloads
  • Catalog
  • Scan demo software
Watch webinars from our Application Experts
More
Warranty
  • Manufacturer’s warranty
  • Activate your warranty
Services
  • Service offers
empty
Register for warranty
activation
More
Profile
  • About us
  • Certification
  • They trust us
Human Resources
  • We are hiring!
News
  • Latest news
  • Exhibitions
  • Press
Profile
More
Contact us
  • Sales teams
  • Application Support
  • Customer support
  • Press
Need help?
  • Info request
empty
Contact us if you have any questions about our products!
More
Interscience for microbiology
  • PRODUCTS
    • Sample preparation
    • Gravimetric dilutors
    • Lab blenders
    • NEWDispensing pumps
    • Lab accessories
    • Bacterial analysis
    • Automatic platers
    • NEWColony counters and inhibition zone readers
    • Real-time incubator and colony counter
    • NEWPetri dish labeling solution
    • Consumables
    • Blender bags with filter
    • Blender bags without filter
    • Blender bags with culture media
    • Sterile sampling bags
    • Autoclave deodorants
  • APPLICATIONS
    • Sectors
    • Food
    • Pharmaceutical
    • Cosmetic
    • Environment
    • Veterinary
    • Public research
    • Solutions
    • BagSystem
    • Plate & Count system
    • JumboLine
    • Steriwater
    • Application advice
    • Comparison of manual and automatic methods in microbiology
    • Why use a filter bag?
    • The Spiral plating technique
  • RESOURCES
    • Scientific library
    • Application notes
    • Scientific articles
    • Scientific posters
    • Appli’News
    • Training
    • Webinars
    • Downloads
    • Catalog
    • Scan demo software
  • SUPPORT
    • Warranty
    • Manufacturer’s warranty
    • Activate your warranty
    • Services
    • Service offers
    • empty
  • COMPANY
    • Profile
    • About us
    • Certification
    • They trust us
    • Human Resources
    • We are hiring!
    • News
    • Latest news
    • Exhibitions
    • Press
  • CONTACT
    • Contact us
    • Sales teams
    • Application Support
    • Customer support
    • Press
    • Need help?
    • Info request
    • empty
 
  • Home
  • APPLICATIONS
  • Sectors

Sectors

Food
Food
Pharmaceutical
Pharmaceutical
Cosmetic
Cosmetic
Environment
Environment
Veterinary
Veterinary
Public research
Public research
Sample preparation
  • Gravimetric dilutors
  • Lab blenders
  • NEWDispensing pumps
  • Lab accessories
Bacterial analysis
  • Automatic platers
  • NEWColony counters and inhibition zone readers
  • Real-time incubator and colony counter
  • NEWPetri dish labeling solution
Consumables
  • Blender bags with filter
  • Blender bags without filter
  • Blender bags with culture media
  • Sterile sampling bags
  • Autoclave deodorants
Catalog cover Discover the catalog
    APPLICATIONS
    Sectors
    • Food
    • Pharmaceutical
    • Cosmetic
    • Environment
    • Veterinary
    • Public research
    Solutions
    • BagSystem
    • Plate & Count system
    • JumboLine
    • Steriwater
    Application advice
    • Comparison of manual and automatic methods in microbiology
    • Why use a filter bag?
    • The Spiral plating technique
    RESOURCES
    Scientific library
    • Application notes
    • Scientific articles
    • Scientific posters
    • Appli’News
    Training
    • Webinars
    Downloads
    • Catalog
    • Scan demo software
    SUPPORT
    Warranty
    • Manufacturer’s warranty
    • Activate your warranty
    Services
    • Service offers
    empty
    COMPANY
    Profile
    • About us
    • Certification
    • They trust us
    Human Resources
    • We are hiring!
    News
    • Latest news
    • Exhibitions
    • Press
    CONTACT
    Contact us
    • Sales teams
    • Application Support
    • Customer support
    • Press
    Need help?
    • Info request
    empty
Interscience More than 45 years of
microbiology expertise

<:interscience:concu_et_fabrique_en_france:Designed and made in France

Logos pied de page du site
  • Site Map
  • Legal info
  • General terms and conditions of sale

© Interscience 2025. All rights reserved

In compliance with international standards

Read more
ISO 7218

MICROBIOLOGY OF FOOD AND ANIMAL FEEDING STUFFS
General requirements and guidance for microbiological examinations

ISO 4833

FOOD MICROBIOLOGY
Horizontal method for the enumeration of microorganisms

European Pharmacopoeia

The European Pharmacopoeia is a unique reference work on the quality control of medicines in the countries that are signatories to the Convention relating to its elaboration.

EUCAST CA-SFM

Following the recommendations of the WHO Expert Committee on Biological Standardisation (technical reports no. 610, 1977), the French Society of Microbiology created a Committee on Antibiogram (CA-SFM) to determine the critical values that delimit the clinical categories (previously therapeutic categories) and to propose a guide for the determination of bacterial susceptibility to antibiotics in association with EUCAST. The critical values defined for the concentrations and diameters of the inhibition zones, as well as recommendations specific to certain species or groups of antibiotics are published in this press release.

ISO 6887

MICROBIOLOGY
General guidelines for the preparation of dilutions for microbiological examination

FDA BAM

BACTERIOLOGICAL ANALYTICAL MANUAL

Read more

Application notes

  • Dispensing repeatability of 9 mL from a 2-liter bottle with FlexiPump

    Aim: Evaluate the repeatability of a volume dispensed consecutively, after a FlexiPump calibration, from a FlexiPump calibration from a 2L diluent bottle (tube weight at the bottom and bottle filled for calibration).

    Conclusion: From the results obtained in this test, we can conclude that dispensing successive doses with the FlexiPump, from a 2-liter bottle of diluent, shows excellent repeatability. There is no drift in dispensing volume as the bottle empties.

    Read more (PDF - 251.2 ko)
  • Dispensing repeatability of 9 mL diluent bag with FlexiPump

    Aim: Evaluate the repeatability of a consecutively dispensed volume, after instrument calibration, from a 2L diluent bag.

    Conclusion: From the results obtained in this test, we can conclude that dispensing successive doses with the FlexiPump, from a diluent bag, shows excellent repeatability. There is no drift in dispensing volume as the bag empties.

    Read more (PDF - 262 ko)
  • 50 ML dispensing test with FlexiPump Pro

    Aim: Check the dispensing accuracy of a 50 mL volume with a FlexiPump Pro peristaltic pump, with a dispensing time of less than 4/5 seconds.

    Conclusion: The FlexiPump Pro is accurate for a 50 mL dispense, under the conditions described above. Note that under these conditions, each dispense took 2.7s.

    Read more (PDF - 162.7 ko)
  • Validation of easySpiral/easySpiral Pro plating
    1. Plating validation easySpiral/easyeasySpiral Pro in decreasing exponential mode
      1. Aim: To study the reliability of easySpiral/easySpiral Pro plating in decreasing exponential mode (known as the Spiral method) by carrying out a comparative study with the reference method "manual surface plating" (known as the classic technique).
      2. Conclusion: Our results show a strong correlation (R2 ≥ 0.982) between plating in Spiral mode using the easySpiral and the conventional method. Also, the average difference in log CFU/mL between the two methods is 12 times less than the maximum difference, and therefore not significant.
    2. Cleaning efficiency of easySpiral/easyeasySpiral Pro
      1. Aim: Ensure that the easySpiral/easySpiral Pro stylus is cleaned between each sample run. Check the effectiveness of stylus disinfection by inoculating with sterile diluent.
      2. Conclusion: The study shows that for all six bacterial strains, cleaning in either long or short mode enables disinfection of the stylus and avoids contamination between samples. Three disinfectants were tested: ethanol 70%, bleach 1% and a formulation based on hydrogen peroxide (3%) + peracetic acid (0.08%). Other formulations with slightly different concentrations of H2O2 and APA may also be effective.
    Read more (PDF - 824.6 ko)
  • Scan 1200: performance evaluation

    Aim: The aim of this study was to evaluate the performance of the Scan 1200 by comparing manual and automatic counting. For optimal comparison, Petri dishes were plated and incubated in our R&D laboratory, using standard methods to reproduce normal laboratory conditions. The same technician then counted the colonies with a Scan 1200 and manually to obtain results for evaluating the accuracy of the Scan. This document also contains a study of the analysis time per dish and an estimate of the time spent by the laboratories.

    Conclusion: Tests show in a variety of ways (regression line, correlation coefficient, average Log value difference, and ISO 7218:2007) that Scan 1200:
    — Enables faster counting (up to 80% time saving).
    — Counts as well as another user (strong relationship between the 2 methods, with an average difference of 2.35% per dish).

    The Scan 1200 is an excellent tool for laboratories needing to count large numbers of dishes accurately and without wasting time. All results can be saved in specific files (called sessions) which contain all dish photos and counts, guaranteeing analysis quality and perfect traceability.

    Read more (PDF - 3.2 Mo)
  • ScanStation in the food industry

    Aim: The aim of this study was to evaluate the performance of the ScanStation 100 by comparing the manual and automatic methods for food and milk payment analysis. For an optimal comparison, 1238 food samples, in duplicate, were carried out on a multitude of micro-organisms according to the laboratory’s reference methods. This document also contains curves showing the evolution of bacterial load over time.

    Conclusion: Interpretation of these curves shows that the number of CFUs evolves up to 15 h of incubation. Thereafter, the number of CFU remains constant. Real-time counting during incubation enables us to quickly determine the presence of contamination, for example, and thus to define corrective actions before the end of incubation.

    Read more (PDF - 241.3 ko)
  • ScanStation in the food industry (study conducted on Symphony and TBX media)

    Aim: The aim of this study was to evaluate the performance of the ScanStation (ISS) by comparing manual and automatic counting on the analysis of samples seeded on Symphony and TBX media.

    Conclusion: The difference in the majority of counts does not exceed the 0.3 log CFU limit. These results show no significant difference. By reading the "Time to Result" of the various microorganisms grown on Symphony and TBX media, it is possible to anticipate count results, enabling the user to define corrective action more quickly.

    Read more (PDF - 882.1 ko)
  • ScanStation performance (study conducted with Salmonella typhimurium and Listeria monocytogenes)

    Aim: The aim of this study was to evaluate the performance of the ScanStation (ISS) by comparing manual and automatic decomposition of pure cultures of Salmonella typhimurium and Listeria monocytogenes.

    Conclusion: The difference in the majority of counts does not exceed the 0.3 log CFU limit. These results show no significant difference. Reading the "Time to Result" for Salmonella typhimurium and Listeria monocytogenes makes it possible to anticipate count results, enabling the user to define corrective action more quickly.

    Read more (PDF - 1.1 Mo)
  • Counting waterborne pathogens with ScanStation, a real-time incubation and counting station. Use of filtration membranes

    Aim: The objective of this study was to evaluate the performance of the ScanStation to count in real time colonies on membrane filtration. Enumeration was performed on waterborne pathogens that have been linked to healthcare-associated infections (HAIs). Bacterial suspensions were passed through filtration membranes that were deposited on Petri dish. Colonies were manually counted and results were compared with automatic counts performed by the ScanStation.

    Conclusion: ScanStation performs well in counting colonies on filtration membranes in real time. For the seven strains tested, the automatic and manual counts are similar when bacterial suspensions are filtered on white polycarbonate membranes (without grids). For best automatic counts in this case, the recommended light configuration is white background (light from below). This study shows that bacterial colonies can be efficiently counted with ScanStation.

    Read more (PDF - 6.8 Mo)
  • Robustness tests on ScanStation

    Aim: The aim of this study is to evaluate the performance of ScanStation (ISS) by comparing manual and automatic counting of plated samples for robustness counting assessment.

    Conclusion: ScanStation’s robustness tests showed reproducible data under both intra- and inter-machine conditions.

    Read more (PDF - 313.9 ko)

They trust us

Logo - ANSES

Logo - CPC

Logo - CEA

Logo - CNRS

Logo - CRCM

Logo - FDA

Logo - Inserm

Logo - Institut Pasteur

Logo - Nanjing

Logo - Peking university

Logo - University

Logo - USDA

Logo Ciri

CIRI
International research centre for infectious diseases

“ “
Using the l’easySpiral Pro saves us valuable time and allows us to be more reproducible.
AQMC

AQMC Laboratory
Consumer Safety and Health

“ “
3 dilution speeds to adapt to any type of matrix with the DiluFlow Elite dilutor
Terana

TERANA Public Analysis Laboratory
Services provided by the Conseil départemental du Puy-de-Dôme, France

“ “
We have a DiluFlow Elite double pump with booster kit.

The different sectors of activity

Our products are also used for microbiological analysis in the food, environmental, pharmaceutical, cosmetic, animal health and public institutes sectors.

Food

Read more

Environment

Read more

Pharmaceutical

Read more

Cosmetic

Read more

Veterinary

Read more